6. ELRS, Finder & Passthrough
LiteTX controls the T8L's built-in ExpressLRS module directly with live telemetry and full parameter access.
Binding a Receiver
You can start ExpressLRS Binding in two ways:
- From the radio (default shortcut): Hold the
Mbutton for 2 seconds. - From the WebUI: Open RF Settings → RF Module, find Bind, and click Start.
(If you use an ExpressLRS Binding Phrase, your receiver connects automatically without pressing Bind.)
ELRS Settings & Firmware Version (RF Settings → RF Module)
When RF is ON, LiteTX loads your ExpressLRS settings automatically:
- RF Toggle: Turns the RF module ON or OFF globally (also mapped to
M + Powerby default). - Receiver / Model ID (
0–63): Saved per model. Each model slot can have its own Model Match ID and ExpressLRS profile (Packet Rate, Telem Ratio, Switch Mode, TX Power, Dynamic Power). - TX Params / RX Params: Switch between your transmitter module and a connected receiver. The ExpressLRS firmware version (e.g.
v3.5.x) appears right next to the device name. - Enable WiFi: Starts WiFi mode on the ELRS module so you can open its web interface (
10.0.0.1).
ELRS Finder — Lost-Model Locator
Use ELRS Finder to walk straight toward a downed aircraft using live signal strength (Geiger-counter style):
- Start / Stop:
- Press
MShort Click on the radio (default), OR - Flip a switch assigned to ELRS Finder under Special Functions, OR
- Open RF Settings → ELRS Finder and click Start Finder.
- Press
- While connected to the model:
- Beeps and
1–4bar LEDs flash faster as you get closer (1.2 sapart when far, up to rapid beeps when right beside the model). - Adjust Far dBm (default
-110 dBm) and Near dBm (default-40 dBm) in the WebUI to match your flying spot.
- Beeps and
- When disconnected / no link:
- All 4 bar LEDs blink slowly with a slow beep so you know right away there is no link yet, until the signal comes back or you turn Finder off.
Updating the Built-In ELRS Module (Passthrough)
You can update the T8L's ExpressLRS module over USB-C using ExpressLRS Configurator:
- Connect your radio to the LiteTX WebUI in USB VCP mode (hold
M+ Power) with RF ON. - Go to System → Backup & DFU and click Start Passthrough.
- Click Disconnect in the WebUI to free the COM port.
- Open ExpressLRS Configurator, pick the RadioMaster T8L target with EdgeTXPassthrough / UART, choose the radio's COM port, and click Flash.
- When flashing finishes, hold the
Powerbutton for 3 seconds to exit Passthrough and restart the ELRS module normally.